back to Machine Log

ROM Fault?

Prev Entry Next Entry

To date it has been possible to demonstrate that:

This still leaves two general possibilities for the ongoing failure:

Considering these, it seemed simplest to instrument the entire ROM output and assess if the microcode values were in agreement with the available listings.

Suggestion of ROM Fault

Setting up the HP16500C to monitor all ROM address lines and output lines while the machine was attempting to run microcode soon showed a suspicious finding.

The 16500C has a handy feature, a live view of the activity on each signal that is connected. When monitoring an active machine most of the signals will be dynamic and this is shown by a vertical double-headed arrow. Signals permanently high or low display the appropriate horizontal bar.

When connected to the complete 42-bit microcode word, the live view feature shows that 3-bit BI value in the has varying bits 0 and 2 but bit 1 is always zero.

The microcode BI field controls data input to the ALU. A stuck bit in this field would clearly cause major disruption to the microcode and would be sufficient to explain the dead machine.